Acetyl Chloride
- CAS Number
- 75-36-5
- HSN Code
- 29159010
- Molecular Formula
- CH3COCl
- Catalogue Number
- AL0091A
- Purity
- 99%
- Molecular Weight
- 78.50 g/mol
Complies with : IP | BP | USP | EP | ACS
ISO 9001
ISO 14001
GMP
COA with every batch
Key Properties
Acetyl chloride is an acyl chloride. It is functionally related to an acetic acid.
Also known as Acetyl chloride, Ethanoic chloride.
- Catalogue No.
- AL0091A
- CAS Number
- 75-36-5
- Molecular Formula
- CH3COCl
- Molecular Weight
- 78.50 g/mol
- HSN Code
- 29159010
- Grade
- AR grade
- Product Form
- Substance
Melting point: -112.7 °C; Boiling point: 51 °C; Flash point: 5 °C (41 °F) - closed cup; Density: 1.1051g/cu cm at 20 °C; Solubility: Decomposed violently by water or alcohol.
- Appearance
- Liquid
- Shelf Life
- -
- Packaging
- Available in: 500 ml glass bottle
- Storage
- Fireproof. Store in an area without drain or sewer access. Separated from incompatible materials. See Chemical Dangers. Dry. Well closed.
1.1 — Product identifier
- Chemical Name
- Acetyl Chloride
- Catalogue No.
- AL0091A
- Product form
- Substance
- CAS Number
- 75-36-5
- EC Number
- 200-865-6
- Grade
- AR grade
- EC Index Number
- 607-004-00-8
- Chemical Formula
- CH3COCl
- HSN Code
- 29159010
- Synonyms
- Acetyl chloride, Ethanoic chloride
1.2 — Relevant identified uses of the substance or mixture and uses advised against
- Use of the substance/mixture
- Reagent for acetylation in organic synthesis
- Uses advised against
- Not specified
1.3 — Details of the supplier of the safety data sheet
- Company identification
- Address:- 102, B wing, Savgan Heights, RTO Lane,Andheri (W), Mumbai-400 053Maharashtra, India.
1.4 — Emergency Contact Details
- Phone / e-Mail
- Phone : +91 22 26317055 Mobile : +91 9820385757 e-mail : info@alphachemika.co.in
2.1 — Classification of the substance or mixture
- Classification according to Regulation (EC) No 1272/2008
- Flam. Liq. 2; Skin Corr. 1B; Eye Dam. 1
- Classification source
- ECHA C&L Inventory via PubChem CID 6367 - hazard classes notified by at least 50% of companies; pictograms and signal word derived from those statements
2.2 — Label elements
- Hazard pictograms
- Flammable, Corrosive
- Signal word
- Danger
- Hazard statements
- H225: Highly Flammable liquid and vapor; H314: Causes severe skin burns and eye damage; H318: Causes serious eye damage
2.3 — Other hazards
- Other hazards
- Corrosive to metals, may cause severe burns to skin and eyes.
3.1 — Substance
- Name
- Acetyl Chloride
- CAS No.
- 75-36-5
4.1 — Description of first aid measures
- First-aid measures after inhalation
- Move to fresh air. If breathing is difficult, give oxygen. Seek medical attention.
- First-aid measures after skin contact
- IMMEDIATELY flood affected skin with water while removing and isolating all contaminated clothing. Gently wash all affected skin areas thoroughly with soap and water.
- First-aid measures after eye contact
- First check the victim for contact lenses and remove if present. Flush victim's eyes with water or normal saline solution for 20 to 30 minutes while simultaneously calling a hospital or poison control center.
- First-aid measures after ingestion
- Do not induce vomiting. Rinse mouth and seek medical attention immediately.
4.2 — Most important symptoms and effects, both acute and delayed
- Symptoms relating to use
- Burning sensation, coughing, shortness of breath, and irritation of the skin and eyes.
4.3 — Indication of any immediate medical attention and special treatment needed
- General information
- Treat symptomatically. Show this safety data sheet to the treating physician.
5.1 — Extinguishing media
- Suitable extinguishing media
- Dry powder, dry sand. Unsuitable extinguishing media: Do NOT use water jet.
- Unsuitable extinguishing media
- Not specified
5.2 — Special hazards arising from the substance or mixture
- Special procedures
- Varpors are heavier than air and may travel to a source of ignition and flash back. Closed containers may rupture violently when heated.
5.3 — Advice for firefighters
- Protection during firefighting
- Do not enter fire area without proper protective equipment, including respiratory protection.
6.1.1 — For non-emergency personnel
- Emergency procedures
- Evacuate area. Wear appropriate protective equipment. Contain and absorb spill with inert material.
6.3 — Methods and material for containment and cleaning up
- Methods for cleaning up
- Evacuate danger area! Consult an expert! Personal protection: complete protective clothing including self-contained breathing apparatus. Do NOT let this chemical enter the environment. Do NOT wash away into sewer. Collect leaking and spilled liquid in sealable containers as far as possible.
6.4 — Reference to other sections
- Reference
- Not specified
7.1 — Precautions for safe handling
- Precautions for safe handling
- Use in a fume hood. Wear appropriate personal protective equipment including gloves and goggles.
- Hygiene measures
- Wash hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work.
7.2 — Conditions for safe storage, including any incompatibilities
- Storage conditions
- Fireproof. Store in an area without drain or sewer access. Separated from incompatible materials. See Chemical Dangers. Dry. Well closed.
8.2 — Exposure controls
- Hand protection
- Handle with gloves.
- Eye protection
- Tightly fitting safety goggles. Faceshield (8-inch minimum).
- Skin and body protection
- Wear suitable protective clothing
- Respiratory protection
- Use appropriate respiratory protection if ventilation is inadequate.
9.1 — Information on basic physical and chemical properties
- Physical state
- Liquid
- Colour
- Colorless to pale yellow
- Odour
- Pungent odor
- Odour threshold
- Not specified
- pH value
- Not applicable
- Relative evaporation rate (butylacetate=1)
- Not specified
- Melting point
- -112.7 °C
- Freezing point
- Not specified
- Boiling point
- 51 °C
- Flash point
- 5 °C (41 °F) - closed cup
- Auto-ignition temperature
- 734 °F (390 °C)
- Decomposition temperature
- Not specified
- Flammability (solid, gas)
- Flammable liquid
- Vapour pressure
- 287 mm Hg at 25 °C
- Relative vapour density at 20°C
- 2.70 (Air = 1)
- Density
- 1.1051g/cu cm at 20 °C
- Solubility
- Decomposed violently by water or alcohol
- Log Pow
- -0.47
- Viscosity, kinematic
- Not specified
- Viscosity, dynamic
- Not specified
- Explosive properties
- Not explosive
- Oxidising properties
- Not oxidizing
- Explosive limits
- Not specified
10.1 — Reactivity
- Reactivity
- Reacts violently with water, releasing hydrochloric acid and heat.
10.2 — Chemical stability
- Chemical stability
- Stable under recommended storage conditions.
10.3 — Possibility of hazardous reactions
- Possibility of hazardous reactions
- Decomposes on heating and on burning. This produces toxic and corrosive fumes including hydrogen chloride (see ICSC 0163) and phosgene (see ICSC 0007). Reacts with moisture in the air.
10.4 — Conditions to avoid
- Conditions to avoid
- Avoid contact with incompatible materials and excessive heat.
10.5 — Incompatible materials
- Incompatible materials
- Water, strong bases, strong oxidizers, amines.
10.6 — Hazardous decomposition products
- Hazardous decomposition products
- Hazardous decomposition products formed under fire conditions - Carbon oxides, hydrogen chloride gas.
11.1 — Information on toxicological effects
- Acute toxicity
- LD50 Rat oral 910 mg/kg
- Skin corrosion/irritation
- H314: Causes severe skin burns and eye damage
- Serious eye damage/irritation
- H318: Causes serious eye damage
- Respiratory or skin sensitisation
- Not classified (based on available data)
- Germ cell mutagenicity
- Not classified (based on available data)
- Carcinogenicity
- Not classified (based on available data)
- Specific target organ toxicity (single exposure)
- Not classified (based on available data)
- Specific target organ toxicity (repeated exposure)
- Not classified (based on available data)
12.1 — Toxicity
- Toxicity information
- Not specified
12.2 — Persistence - degradability
- Persistence - degradability
- Not specified
12.3 — Bioaccumulative potential
- Bioaccumulative potential
- Not specified
12.4 — Mobility in soil
- Mobility in soil
- Not specified
12.6 — Other adverse effects
- Environmental precautions
- Not specified
13.1 — Waste treatment methods
- Additional Info
- Dispose of contents/container in accordance with local, regional, national and international regulations.
14.1 — UN number
- UN-No. (ADR)
- 1717
- UN-No. (IMDG)
- 1717
- UN-No. (IATA)
- 1717
- UN-No. (ADN)
- 1717
- UN-No. (RID)
- 1717
14.2 — UN proper shipping name
- Proper Shipping Name (ADR)
- Acetyl Chloride
- Proper Shipping Name (IMDG)
- Acetyl Chloride
- Proper Shipping Name (IATA)
- Acetyl Chloride
- Proper Shipping Name (ADN)
- Acetyl Chloride
- Proper Shipping Name (RID)
- Acetyl Chloride
14.3 — Transport hazard class(es)
- Transport hazard class(es)
- 3 (8)
14.4 — Packing group
- Packing group (ADR)
- II
- Packing group (IMDG)
- II
- Packing group (IATA)
- II
- Packing group (ADN)
- II
- Packing group (RID)
- II
14.5 — Environmental hazards
- Dangerous for the environment
- Not specified
- Marine pollutant
- Not specified
- Other information
- No supplementary information available
15.1 — Safety, health and environmental regulations/legislation specific for the substance or mixture
- 15.1.1 EU-Regulations
- Not specified
Used in precision acetylation reactions in analytical and preparative organic synthesis. It is also utilized in the production of pharmaceuticals, agrochemicals, and other organic compounds.
ISO 9001
ISO 14001
GMP
COA with every batch
- Batch Number
- AL-2026-AL0016D
- Manufacturing Date
- September-2026
- Expiry Date
- September-2031
- Molecular Weight
- 78.50 g/mol
| Test | Standard | Observed |
|---|---|---|
| Purity | 99% min | 99.5% |
| Density | 1.10 g/mL | 1.10 g/mL |
| Boiling Point | 51.2 °C | 51.5 °C |
| Appearance | Colorless to pale yellow | Colorless |
| Flash Point | 24 °C | 25 °C |
The above product is expected to comply with AR grade grade specification.
Technical Data Sheet
| Grade | Assay/Purity | Melting/Boiling Point | Moisture/LOD | Residue on Ignition | Related Substances | Solubility |
|---|---|---|---|---|---|---|
| AR grade | 99% | m.p. -112.7 °C; b.p. 51 °C | Not specified | Not specified | Not specified | Decomposed violently by water or alcohol |
Related Products
View AllWhy buy from Alpha Chemika
What Our Scientific & Industrial Customers Say
“Speedy delivery, professional staff.”
“One shop stop for all laboratory chemicals requirements.”
“Exactly as advertised.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Completely satisfied with the products and services.”
“Speedy delivery, professional staff.”
“One shop stop for all laboratory chemicals requirements.”
“Exactly as advertised.”
“One shop stop for all laboratory chemicals requirements.”
“Exactly as advertised.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“Exactly as advertised.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Completely satisfied with the products and services.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Completely satisfied with the products and services.”
“Speedy delivery, professional staff.”
“Completely satisfied with the products and services.”
“Speedy delivery, professional staff.”
“One shop stop for all laboratory chemicals requirements.”
Common Questions About Laboratory Chemicals & Solutions
Find answers to common questions about laboratory chemicals, product selection, documentation, ordering, and technical support. Whether you are sourcing chemicals for research, testing, education, manufacturing, or industrial applications, these FAQs can help you make informed purchasing decisions.
Alpha Chemika offers a wide range of laboratory chemicals, reagents, solvents, and specialty products for research, testing, educational, pharmaceutical, and industrial applications.
Product selection depends on factors such as application, required purity, grade, specifications, and intended use. Our team can help you identify suitable products based on your technical requirements.
Yes. Relevant product information and technical documentation can be provided to help you evaluate products for quality, handling, compliance, and application requirements.
Yes. You can share your product list, required quantities, specifications, and delivery requirements with our team for a tailored quotation.
Yes. We support requirements from research laboratories, educational institutions, pharmaceutical companies, manufacturers, distributors, and other scientific and industrial organizations.
Connect with Us for Your Requirements
Have a specific product requirement or need help finding the right chemical for your application? Share your requirements with our team, and we will help you identify suitable products, specifications, quantities, and procurement options.