Ethylene chlorohydrin
- CAS Number
- 107-07-3
- HSN Code
- 29051690
- Molecular Formula
- C2H5ClO
- Catalogue Number
- AL2070
- Purity
- ≥ 99%
- Molecular Weight
- 80.51 g/mol
Complies with : IP | BP | USP | EP | ACS
ISO 9001
ISO 14001
GMP
COA with every batch
Key Properties
2-chloroethanol is a chloroethanol carrying a chloro substituent at position 2. It has a role as a xenobiotic metabolite.
Also known as 2-chloroethanol.
- Catalogue No.
- AL2070
- CAS Number
- 107-07-3
- Molecular Formula
- C2H5ClO
- Molecular Weight
- 80.51 g/mol
- HSN Code
- 29051690
- Grade
- 99%
- Product Form
- Substance
Melting point: -67.5 °C; Boiling point: 128-130 °C @ 760 MM HG; Flash point: 105 °F (40 °C) (open cup); Density: 1.197 @ 20 °C/4 °C; Solubility: greater than or equal to 100 mg/mL at 66 °F.
- Appearance
- Colorless liquid
- Shelf Life
- -
- Packaging
- Available in: 500 ml glass bottle with tin cap, 2.5 Lt glass bottle with tin cap
- Storage
- Fireproof. Separated from strong bases, oxidants and food and feedstuffs. Dry. Well closed.
1.1 — Product identifier
- Chemical Name
- Ethylene chlorohydrin
- Catalogue No.
- AL2070
- Product form
- Substance
- CAS Number
- 107-07-3
- EC Number
- 203-459-7
- Grade
- 99%
- EC Index Number
- 603-007-00-5
- Chemical Formula
- C2H5ClO
- HSN Code
- 29051690
- Synonyms
- 2-chloroethanol
1.2 — Relevant identified uses of the substance or mixture and uses advised against
- Use of the substance/mixture
- Synthetic intermediate in chemical synthesis
- Uses advised against
- Not specified
1.3 — Details of the supplier of the safety data sheet
- Company identification
- Address:- 102, B wing, Savgan Heights, RTO Lane,Andheri (W), Mumbai-400 053Maharashtra, India.
1.4 — Emergency Contact Details
- Phone / e-Mail
- Phone : +91 22 26317055 Mobile : +91 9820385757 e-mail : info@alphachemika.co.in
2.1 — Classification of the substance or mixture
- Classification according to Regulation (EC) No 1272/2008
- Flam. Liq. 3; Met. Corr. 1; Acute Tox. 2; Acute Tox. 1; Eye Dam. 1; Aquatic Chronic 2
- Classification source
- ECHA C&L Inventory via PubChem CID 34 - hazard classes notified by at least 50% of companies; pictograms and signal word derived from those statements
2.2 — Label elements
- Hazard pictograms
- Flammable, Corrosive, Acute Toxic, Environmental Hazard
- Signal word
- Danger
- Hazard statements
- H226: Flammable liquid and vapor; H290: May be corrosive to metals; H300: Fatal if swallowed; H310: Fatal in contact with skin; H318: Causes serious eye damage; H330: Fatal if inhaled; H411: Toxic to aquatic life with long lasting effects
2.3 — Other hazards
- Other hazards
- Highly toxic and flammable; may cause skin burns and respiratory irritation.
3.1 — Substance
- Name
- Ethylene chlorohydrin
- CAS No.
- 107-07-3
4.1 — Description of first aid measures
- First-aid measures after inhalation
- If this chemical has been inhaled, remove the exposed person to fresh air at once. If breathing has stopped, perform artificial respiration. Keep the person warm and at rest.
- First-aid measures after skin contact
- If this chemical contacts the skin, immediately flush the contaminated skin with water. If this chemical penetrates the clothing, immediately remove the clothing and flush the skin with water. Get medical attention promptly.
- First-aid measures after eye contact
- If this chemical contacts the eyes, immediately wash (irrigate) the eyes with large amounts of water, occasionally lifting the lower and upper lids. Get medical attention immediately.
- First-aid measures after ingestion
- If this chemical has been swallowed, get medical attention immediately.
4.2 — Most important symptoms and effects, both acute and delayed
- Symptoms relating to use
- Symptoms of exposure may include headache, dizziness, nausea, vomiting, and skin irritation.
4.3 — Indication of any immediate medical attention and special treatment needed
- General information
- Treat symptomatically. Show this safety data sheet to the treating physician.
5.1 — Extinguishing media
- Suitable extinguishing media
- Water spray, carbon dioxide, dry chemical powder, foam.
- Unsuitable extinguishing media
- Not specified
5.2 — Special hazards arising from the substance or mixture
- Special procedures
- Vapors are heavier than air and may flash back to a source of ignition.
5.3 — Advice for firefighters
- Protection during firefighting
- Do not enter fire area without proper protective equipment, including respiratory protection.
6.1.1 — For non-emergency personnel
- Emergency procedures
- Evacuate area and ventilate. Use appropriate protective equipment. Contain and absorb spill with inert material.
6.3 — Methods and material for containment and cleaning up
- Methods for cleaning up
- Personal protection: complete protective clothing including self-contained breathing apparatus. Collect leaking and spilled liquid in sealable containers as far as possible. Absorb remaining liquid in sand or inert absorbent. Then store and dispose of according to local regulations.
6.4 — Reference to other sections
- Reference
- Not specified
7.1 — Precautions for safe handling
- Precautions for safe handling
- Handle under a fume hood with appropriate PPE. Avoid skin and eye contact.
- Hygiene measures
- Wash hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work.
7.2 — Conditions for safe storage, including any incompatibilities
- Storage conditions
- Fireproof. Separated from strong bases, oxidants and food and feedstuffs. Dry. Well closed.
8.2 — Exposure controls
- Hand protection
- Protective gloves (e.g. nitrile rubber)
- Eye protection
- Chemical safety goggles or safety glasses
- Skin and body protection
- Wear suitable protective clothing
- Respiratory protection
- Use appropriate respiratory protection if ventilation is inadequate.
9.1 — Information on basic physical and chemical properties
- Physical state
- Liquid
- Colour
- Colorless
- Odour
- Faint ether-like odor.
- Odour threshold
- Not specified
- pH value
- Not specified
- Relative evaporation rate (butylacetate=1)
- Not specified
- Melting point
- -67.5 °C
- Freezing point
- Not specified
- Boiling point
- 128-130 °C @ 760 MM HG
- Flash point
- 105 °F (40 °C) (open cup)
- Auto-ignition temperature
- 797 °F; 425 °C
- Decomposition temperature
- Not specified
- Flammability (solid, gas)
- Flammable liquid
- Vapour pressure
- Vapor pressure = 7.18 mm Hg @ 25 °C
- Relative vapour density at 20°C
- 2.78 (AIR= 1)
- Density
- 1.197 @ 20 °C/4 °C
- Solubility
- greater than or equal to 100 mg/mL at 66 °F
- Log Pow
- -0.06
- Viscosity, kinematic
- Not specified
- Viscosity, dynamic
- Not specified
- Explosive properties
- Not specified
- Oxidising properties
- Not specified
- Explosive limits
- Not specified
10.1 — Reactivity
- Reactivity
- Reacts with strong oxidizing agents and bases.
10.2 — Chemical stability
- Chemical stability
- Stable under recommended storage conditions.
10.3 — Possibility of hazardous reactions
- Possibility of hazardous reactions
- Decomposes on burning. This produces toxic and corrosive gases of hydrogen chloride and phosgene. Reacts violently with oxidants.
10.4 — Conditions to avoid
- Conditions to avoid
- Avoid contact with incompatible materials and excessive heat.
10.5 — Incompatible materials
- Incompatible materials
- Strong oxidizers, strong bases, and acids.
10.6 — Hazardous decomposition products
- Hazardous decomposition products
- Not specified
11.1 — Information on toxicological effects
- Acute toxicity
- LD50 Rat oral 58 mg/kg; LD50 Rat sc 72 mg/kg; LD50 Rabbit dermal 67.8 mg/kg
- Skin corrosion/irritation
- Not classified (based on available data)
- Serious eye damage/irritation
- H318: Causes serious eye damage
- Respiratory or skin sensitisation
- Not classified (based on available data)
- Germ cell mutagenicity
- Not classified (based on available data)
- Carcinogenicity
- Not classified (based on available data)
- Specific target organ toxicity (single exposure)
- Not classified (based on available data)
- Specific target organ toxicity (repeated exposure)
- Not classified (based on available data)
12.1 — Toxicity
- Toxicity information
- Not specified
12.2 — Persistence - degradability
- Persistence - degradability
- Not specified
12.3 — Bioaccumulative potential
- Bioaccumulative potential
- Not specified
12.4 — Mobility in soil
- Mobility in soil
- Not specified
12.6 — Other adverse effects
- Environmental precautions
- Not specified
13.1 — Waste treatment methods
- Additional Info
- Dispose of contents/container in accordance with local, regional, national and international regulations.
14.1 — UN number
- UN-No. (ADR)
- 1135
- UN-No. (IMDG)
- 1135
- UN-No. (IATA)
- 1135
- UN-No. (ADN)
- 1135
- UN-No. (RID)
- 1135
14.2 — UN proper shipping name
- Proper Shipping Name (ADR)
- Ethylene chlorohydrin
- Proper Shipping Name (IMDG)
- Ethylene chlorohydrin
- Proper Shipping Name (IATA)
- Ethylene chlorohydrin
- Proper Shipping Name (ADN)
- Ethylene chlorohydrin
- Proper Shipping Name (RID)
- Ethylene chlorohydrin
14.3 — Transport hazard class(es)
- Transport hazard class(es)
- 6.1 (3)
14.4 — Packing group
- Packing group (ADR)
- I
- Packing group (IMDG)
- I
- Packing group (IATA)
- I
- Packing group (ADN)
- I
- Packing group (RID)
- I
14.5 — Environmental hazards
- Dangerous for the environment
- Not specified
- Marine pollutant
- Not specified
- Other information
- No supplementary information available
15.1 — Safety, health and environmental regulations/legislation specific for the substance or mixture
- 15.1.1 EU-Regulations
- Not specified
Used as a synthetic intermediate in specialty chemical research, handled with strict exposure controls due to acute toxicity.
ISO 9001
ISO 14001
GMP
COA with every batch
- Batch Number
- AL-2026-AL00688
- Manufacturing Date
- September-2026
- Expiry Date
- September-2031
- Molecular Weight
- 80.51 g/mol
| Test | Standard | Observed |
|---|---|---|
| Assay | ≥ 99% | 99.5% |
| Density | 1.201 g/mL | 1.201 g/mL |
| Boiling Point | 121 °C | 121 °C |
| Moisture Content | ≤ 0.5% | 0.3% |
| Residue on Ignition | ≤ 0.1% | 0.05% |
| Related Substances | None detected | None detected |
The above product is expected to comply with 99% grade specification.
Technical Data Sheet
| Grade | Assay/Purity | Melting/Boiling Point | Moisture/LOD | Residue on Ignition | Related Substances | Solubility |
|---|---|---|---|---|---|---|
| 99% | ≥ 99% | m.p. -67.5 °C; b.p. 128-130 °C @ 760 MM HG | ≤ 0.5% | ≤ 0.1% | None detected | greater than or equal to 100 mg/mL at 66 °F |
Related Products
View AllWhy buy from Alpha Chemika
What Our Scientific & Industrial Customers Say
“Speedy delivery, professional staff.”
“One shop stop for all laboratory chemicals requirements.”
“Exactly as advertised.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Completely satisfied with the products and services.”
“Speedy delivery, professional staff.”
“One shop stop for all laboratory chemicals requirements.”
“Exactly as advertised.”
“One shop stop for all laboratory chemicals requirements.”
“Exactly as advertised.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“Exactly as advertised.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Completely satisfied with the products and services.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Completely satisfied with the products and services.”
“Speedy delivery, professional staff.”
“Completely satisfied with the products and services.”
“Speedy delivery, professional staff.”
“One shop stop for all laboratory chemicals requirements.”
Common Questions About Laboratory Chemicals & Solutions
Find answers to common questions about laboratory chemicals, product selection, documentation, ordering, and technical support. Whether you are sourcing chemicals for research, testing, education, manufacturing, or industrial applications, these FAQs can help you make informed purchasing decisions.
Alpha Chemika offers a wide range of laboratory chemicals, reagents, solvents, and specialty products for research, testing, educational, pharmaceutical, and industrial applications.
Product selection depends on factors such as application, required purity, grade, specifications, and intended use. Our team can help you identify suitable products based on your technical requirements.
Yes. Relevant product information and technical documentation can be provided to help you evaluate products for quality, handling, compliance, and application requirements.
Yes. You can share your product list, required quantities, specifications, and delivery requirements with our team for a tailored quotation.
Yes. We support requirements from research laboratories, educational institutions, pharmaceutical companies, manufacturers, distributors, and other scientific and industrial organizations.
Connect with Us for Your Requirements
Have a specific product requirement or need help finding the right chemical for your application? Share your requirements with our team, and we will help you identify suitable products, specifications, quantities, and procurement options.