Allylamine
- CAS Number
- 107-11-9
- HSN Code
- 29211990
- Molecular Formula
- C3H7N
- Catalogue Number
- AL0173
- Purity
- ≥ 99%
- Molecular Weight
- 57.10 g/mol
Complies with : IP | BP | USP | EP | ACS
ISO 9001
ISO 14001
GMP
COA with every batch
Key Properties
Allylamine appears as a colorless to light yellow colored liquid with a strong ammonia-like odor. Less dense than water.
Also known as 2-Propen-1-amine.
- Catalogue No.
- AL0173
- CAS Number
- 107-11-9
- Molecular Formula
- C3H7N
- Molecular Weight
- 57.10 g/mol
- HSN Code
- 29211990
- Grade
- 99% For Synthesis
- Product Form
- Substance
Melting point: -88.2 °C; Boiling point: 53.5 °C; Flash point: -29 °C (-20 °F) - closed cup; Density: 0.760 at 20 °C/20 °C; Solubility: In water, 1X10+6 mgL at 20 °C miscible/.
- Appearance
- Colorless to light yellow liquid
- Shelf Life
- -
- Packaging
- Available in: 250 ml glass bottle with tin cap, 1 Lt glass bottle with tin cap
- Storage
- Provision to contain effluent from fire extinguishing. Fireproof. Separated from strong oxidants, strong acids and food and feedstuffs. Well closed. Store in an area without drain or sewer access.
1.1 — Product identifier
- Chemical Name
- Allylamine
- Catalogue No.
- AL0173
- Product form
- Substance
- CAS Number
- 107-11-9
- EC Number
- 203-463-9
- Grade
- 99% For Synthesis
- EC Index Number
- 612-005-00-5
- Chemical Formula
- C3H7N
- HSN Code
- 29211990
- Synonyms
- 2-Propen-1-amine
1.2 — Relevant identified uses of the substance or mixture and uses advised against
- Use of the substance/mixture
- Used in the synthesis of specialty polymers and pharmaceuticals.
- Uses advised against
- Not specified
1.3 — Details of the supplier of the safety data sheet
- Company identification
- Address:- 102, B wing, Savgan Heights, RTO Lane,Andheri (W), Mumbai-400 053Maharashtra, India.
1.4 — Emergency Contact Details
- Phone / e-Mail
- Phone : +91 22 26317055 Mobile : +91 9820385757 e-mail : info@alphachemika.co.in
2.1 — Classification of the substance or mixture
- Classification according to Regulation (EC) No 1272/2008
- Flam. Liq. 2; Acute Tox. 3; Acute Tox. 1; Skin Corr. 1A; Eye Dam. 1; Acute Tox. 2; Aquatic Chronic 2
- Classification source
- ECHA C&L Inventory via PubChem CID 7853 - hazard classes notified by at least 50% of companies; pictograms and signal word derived from those statements
2.2 — Label elements
- Hazard pictograms
- Flammable, Corrosive, Acute Toxic, Environmental Hazard
- Signal word
- Danger
- Hazard statements
- H225: Highly Flammable liquid and vapor; H301: Toxic if swallowed; H310: Fatal in contact with skin; H314: Causes severe skin burns and eye damage; H318: Causes serious eye damage; H330: Fatal if inhaled; H411: Toxic to aquatic life with long lasting effects
2.3 — Other hazards
- Other hazards
- Highly toxic and corrosive; may cause severe burns.
3.1 — Substance
- Name
- Allylamine
- CAS No.
- 107-11-9
4.1 — Description of first aid measures
- First-aid measures after inhalation
- Move to fresh air. If breathing is difficult, give oxygen. Seek medical attention immediately.
- First-aid measures after skin contact
- Remove contaminated clothing and wash skin thoroughly with soap and water. Seek medical attention if irritation persists.
- First-aid measures after eye contact
- Rinse cautiously with water for several minutes. Remove contact lenses if present and easy to do. Continue rinsing and seek medical attention.
- First-aid measures after ingestion
- Do not induce vomiting. Rinse mouth and seek medical attention immediately.
4.2 — Most important symptoms and effects, both acute and delayed
- Symptoms relating to use
- Symptoms of exposure may include respiratory distress, skin burns, and eye irritation.
4.3 — Indication of any immediate medical attention and special treatment needed
- General information
- Treat symptomatically. Show this safety data sheet to the treating physician.
5.1 — Extinguishing media
- Suitable extinguishing media
- Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.
- Unsuitable extinguishing media
- Not specified
5.2 — Special hazards arising from the substance or mixture
- Special procedures
- Vapor/air mixtures are explosive.
5.3 — Advice for firefighters
- Protection during firefighting
- Do not enter fire area without proper protective equipment, including respiratory protection.
6.1.1 — For non-emergency personnel
- Emergency procedures
- Evacuate area and ventilate. Wear appropriate protective equipment. Contain and absorb spill with inert material.
6.3 — Methods and material for containment and cleaning up
- Methods for cleaning up
- Remove all ignition sources. Evacuate danger area! Consult an expert! Personal protection: gas-tight chemical protection suit including self-contained breathing apparatus. Do NOT let this chemical enter the environment. Collect leaking liquid in sealable containers.
6.4 — Reference to other sections
- Reference
- Not specified
7.1 — Precautions for safe handling
- Precautions for safe handling
- Use in a fume hood with appropriate PPE including gloves and goggles. Avoid contact with skin and eyes.
- Hygiene measures
- Wash hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work.
7.2 — Conditions for safe storage, including any incompatibilities
- Storage conditions
- Provision to contain effluent from fire extinguishing. Fireproof. Separated from strong oxidants, strong acids and food and feedstuffs. Well closed. Store in an area without drain or sewer access.
8.2 — Exposure controls
- Hand protection
- Handle with gloves.
- Eye protection
- Face shield and safety glasses. Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).
- Skin and body protection
- Wear suitable protective clothing
- Respiratory protection
- Use appropriate respiratory protection if ventilation is inadequate.
9.1 — Information on basic physical and chemical properties
- Physical state
- Liquid
- Colour
- Colorless
- Odour
- Strong ammonia odor causing sneezing and tears
- Odour threshold
- Not specified
- pH value
- Not specified
- Relative evaporation rate (butylacetate=1)
- Not specified
- Melting point
- -88.2 °C
- Freezing point
- Not specified
- Boiling point
- 53.5 °C
- Flash point
- -29 °C (-20 °F) - closed cup
- Auto-ignition temperature
- 705 °F (374 °C)
- Decomposition temperature
- Not specified
- Flammability (solid, gas)
- Flammable liquid
- Vapour pressure
- 242 mm Hg at 25 °C
- Relative vapour density at 20°C
- 2.0 (Air = 1)
- Density
- 0.760 at 20 °C/20 °C
- Solubility
- In water, 1X10+6 mgL at 20 °C miscible/
- Log Pow
- 0.03
- Viscosity, kinematic
- Not specified
- Viscosity, dynamic
- Not specified
- Explosive properties
- Not explosive
- Oxidising properties
- Not oxidizing
- Explosive limits
- Not specified
10.1 — Reactivity
- Reactivity
- Reacts with strong oxidizing agents and acids.
10.2 — Chemical stability
- Chemical stability
- Stable under recommended storage conditions.
10.3 — Possibility of hazardous reactions
- Possibility of hazardous reactions
- Decomposes on burning. This produces toxic fumes including nitrogen oxides. The solution in water is a medium strong base.
10.4 — Conditions to avoid
- Conditions to avoid
- Avoid contact with incompatible materials and excessive heat.
10.5 — Incompatible materials
- Incompatible materials
- Strong oxidizers, acids, and bases.
10.6 — Hazardous decomposition products
- Hazardous decomposition products
- Hazardous decomposition products formed under fire conditions - Carbon oxides, nitrogen oxides (NOx).
11.1 — Information on toxicological effects
- Acute toxicity
- LD50 Rat oral 102 mg/kg; LD50 Rat oral 106 mg/kg; LC50 Rat inhalation 286 ppm/4 hr
- Skin corrosion/irritation
- H314: Causes severe skin burns and eye damage
- Serious eye damage/irritation
- H318: Causes serious eye damage
- Respiratory or skin sensitisation
- Not classified (based on available data)
- Germ cell mutagenicity
- Not classified (based on available data)
- Carcinogenicity
- Not classified (based on available data)
- Specific target organ toxicity (single exposure)
- Not classified (based on available data)
- Specific target organ toxicity (repeated exposure)
- Not classified (based on available data)
12.1 — Toxicity
- Toxicity information
- Not specified
12.2 — Persistence - degradability
- Persistence - degradability
- Not specified
12.3 — Bioaccumulative potential
- Bioaccumulative potential
- Not specified
12.4 — Mobility in soil
- Mobility in soil
- Not specified
12.6 — Other adverse effects
- Environmental precautions
- Not specified
13.1 — Waste treatment methods
- Additional Info
- Dispose of contents/container in accordance with local, regional, national and international regulations.
14.1 — UN number
- UN-No. (ADR)
- 2334
- UN-No. (IMDG)
- 2334
- UN-No. (IATA)
- 2334
- UN-No. (ADN)
- 2334
- UN-No. (RID)
- 2334
14.2 — UN proper shipping name
- Proper Shipping Name (ADR)
- Allylamine
- Proper Shipping Name (IMDG)
- Allylamine
- Proper Shipping Name (IATA)
- Allylamine
- Proper Shipping Name (ADN)
- Allylamine
- Proper Shipping Name (RID)
- Allylamine
14.3 — Transport hazard class(es)
- Transport hazard class(es)
- 6.1
14.4 — Packing group
- Packing group (ADR)
- I
- Packing group (IMDG)
- I
- Packing group (IATA)
- I
- Packing group (ADN)
- I
- Packing group (RID)
- I
14.5 — Environmental hazards
- Dangerous for the environment
- Not specified
- Marine pollutant
- Not specified
- Other information
- No supplementary information available
15.1 — Safety, health and environmental regulations/legislation specific for the substance or mixture
- 15.1.1 EU-Regulations
- Not specified
In the manufacture of mercurial diuretics.
ISO 9001
ISO 14001
GMP
COA with every batch
- Batch Number
- AL-2026-AL0040A
- Manufacturing Date
- September-2026
- Expiry Date
- September-2031
- Molecular Weight
- 57.10 g/mol
| Test | Standard | Observed |
|---|---|---|
| Purity | 99% | 99.5% |
| Density | 0.761 g/mL | 0.760 g/mL |
| Boiling Point | 46 °C | 45.8 °C |
| Moisture Content | ≤ 0.5% | 0.3% |
| Related Substances | Not more than 0.5% | 0.2% |
The above product is expected to comply with 99% For Synthesis grade specification.
Technical Data Sheet
| Grade | Assay/Purity | Melting/Boiling Point | Moisture/LOD | Residue on Ignition | Related Substances | Solubility |
|---|---|---|---|---|---|---|
| 99% For Synthesis | ≥ 99% | m.p. -88.2 °C; b.p. 53.5 °C | ≤ 0.5% | Not applicable | Not more than 0.5% | In water, 1X10+6 mgL at 20 °C miscible/ |
Related Products
View AllWhy buy from Alpha Chemika
What Our Scientific & Industrial Customers Say
“Speedy delivery, professional staff.”
“One shop stop for all laboratory chemicals requirements.”
“Exactly as advertised.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Completely satisfied with the products and services.”
“Speedy delivery, professional staff.”
“One shop stop for all laboratory chemicals requirements.”
“Exactly as advertised.”
“One shop stop for all laboratory chemicals requirements.”
“Exactly as advertised.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“Exactly as advertised.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Completely satisfied with the products and services.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Completely satisfied with the products and services.”
“Speedy delivery, professional staff.”
“Completely satisfied with the products and services.”
“Speedy delivery, professional staff.”
“One shop stop for all laboratory chemicals requirements.”
Common Questions About Laboratory Chemicals & Solutions
Find answers to common questions about laboratory chemicals, product selection, documentation, ordering, and technical support. Whether you are sourcing chemicals for research, testing, education, manufacturing, or industrial applications, these FAQs can help you make informed purchasing decisions.
Alpha Chemika offers a wide range of laboratory chemicals, reagents, solvents, and specialty products for research, testing, educational, pharmaceutical, and industrial applications.
Product selection depends on factors such as application, required purity, grade, specifications, and intended use. Our team can help you identify suitable products based on your technical requirements.
Yes. Relevant product information and technical documentation can be provided to help you evaluate products for quality, handling, compliance, and application requirements.
Yes. You can share your product list, required quantities, specifications, and delivery requirements with our team for a tailored quotation.
Yes. We support requirements from research laboratories, educational institutions, pharmaceutical companies, manufacturers, distributors, and other scientific and industrial organizations.
Connect with Us for Your Requirements
Have a specific product requirement or need help finding the right chemical for your application? Share your requirements with our team, and we will help you identify suitable products, specifications, quantities, and procurement options.