Ammonium Bichromate
- CAS Number
- 7789-09-5
- HSN Code
- 28415090
- Molecular Formula
- (NH4)2Cr2O7
- Catalogue Number
- AL0325
- Purity
- ≥ 99%
- Molecular Weight
- 252.06 g/mol
Complies with : IP | BP | USP | EP | ACS
ISO 9001
ISO 14001
GMP
COA with every batch
Key Properties
Ammonium dichromate is a bright orange red crystalline solid. It is readily ignited and burns producing a voluminous green residue.
Also known as Dichromate of Ammonium.
- Catalogue No.
- AL0325
- CAS Number
- 7789-09-5
- Molecular Formula
- (NH4)2Cr2O7
- Molecular Weight
- 252.06 g/mol
- HSN Code
- 28415090
- Grade
- 99%
- Product Form
- Substance
Melting point: Decomposes 180 °C; Density: 2.155 g/cu cm at 25 °C; Solubility: 35.6 g/100 g water at 20 °C.
- Appearance
- Bright orange-red monoclinic prisms
- Shelf Life
- -
- Packaging
- Available in: 500 gm plastic bottle, 5 Kg plastic bottle
- Storage
- Fireproof. Provision to contain effluent from fire extinguishing. Separated from organic solvents, combustible substances and reducing agents. Well closed. Store in an area without drain or sewer access.
1.1 — Product identifier
- Chemical Name
- Ammonium Bichromate
- Catalogue No.
- AL0325
- Product form
- Substance
- CAS Number
- 7789-09-5
- EC Number
- 232-143-1
- Grade
- 99%
- EC Index Number
- Cr(IV)
- Chemical Formula
- (NH4)2Cr2O7
- HSN Code
- 28415090
- Synonyms
- Dichromate of Ammonium
1.2 — Relevant identified uses of the substance or mixture and uses advised against
- Use of the substance/mixture
- Strong oxidizing agent, used in pyrotechnics and photography.
- Uses advised against
- Not specified
1.3 — Details of the supplier of the safety data sheet
- Company identification
- Address:- 102, B wing, Savgan Heights, RTO Lane,Andheri (W), Mumbai-400 053Maharashtra, India.
1.4 — Emergency Contact Details
- Phone / e-Mail
- Phone : +91 22 26317055 Mobile : +91 9820385757 e-mail : info@alphachemika.co.in
2.1 — Classification of the substance or mixture
- Classification according to Regulation (EC) No 1272/2008
- Ox. Sol. 2; Acute Tox. 3; Acute Tox. 4; Skin Corr. 1B; Skin Sens. 1; Eye Dam. 1; Acute Tox. 2; Resp. Sens. 1; Muta. 1B; Carc. 1B; Repr. 1B; STOT RE 1; Aquatic Acute 1; Aquatic Chronic 1
- Classification source
- ECHA C&L Inventory via PubChem CID 24600 - hazard classes notified by at least 50% of companies; pictograms and signal word derived from those statements
2.2 — Label elements
- Hazard pictograms
- Oxidizer, Corrosive, Acute Toxic, Health Hazard, Environmental Hazard
- Signal word
- Danger
- Hazard statements
- H272: May intensify fire; oxidizer; H301: Toxic if swallowed; H312: Harmful in contact with skin; H314: Causes severe skin burns and eye damage; H317: May cause an allergic skin reaction; H318: Causes serious eye damage; H330: Fatal if inhaled; H334: May cause allergy or asthma symptoms or breathing difficulties if inhaled; H340: May cause genetic defects; H350: May cause cancer; H360FD: May damage fertility; May damage the unborn child; H372: Causes damage to organs through prolonged or repeated exposure; H400: Very toxic to aquatic life; H410: Very toxic to aquatic life with long lasting effects
2.3 — Other hazards
- Other hazards
- Known human carcinogen; may cause respiratory irritation.
3.1 — Substance
- Name
- Ammonium Bichromate
- CAS No.
- 7789-09-5
4.1 — Description of first aid measures
- First-aid measures after inhalation
- Remove to clean air and summon medical attention.
- First-aid measures after skin contact
- Flush with water; if skin irritation develops, get medical attention.
- First-aid measures after eye contact
- Immediately flush with water for at least 15 min. and consult a physician.
- First-aid measures after ingestion
- Vomiting should occur; follow with an emetic of soapy water; give large amounts of water.
4.2 — Most important symptoms and effects, both acute and delayed
- Symptoms relating to use
- Irritation of the respiratory tract, skin, and eyes; potential carcinogenic effects.
4.3 — Indication of any immediate medical attention and special treatment needed
- General information
- Treat symptomatically. Show this safety data sheet to the treating physician.
5.1 — Extinguishing media
- Suitable extinguishing media
- Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.
- Unsuitable extinguishing media
- Not specified
5.2 — Special hazards arising from the substance or mixture
- Special procedures
- May cause fire and explosion; strong oxidizer.
5.3 — Advice for firefighters
- Protection during firefighting
- Do not enter fire area without proper protective equipment, including respiratory protection.
6.1.1 — For non-emergency personnel
- Emergency procedures
- Evacuate area and ventilate. Avoid dust generation.
6.3 — Methods and material for containment and cleaning up
- Methods for cleaning up
- Personal protection: complete protective clothing including self-contained breathing apparatus. Sweep spilled substance into covered non-combustible containers. If appropriate, moisten first to prevent dusting. Carefully collect remainder.
6.4 — Reference to other sections
- Reference
- Not specified
7.1 — Precautions for safe handling
- Precautions for safe handling
- Handle with gloves in a fume hood; avoid inhalation and contact with skin.
- Hygiene measures
- Wash hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work.
7.2 — Conditions for safe storage, including any incompatibilities
- Storage conditions
- Fireproof. Provision to contain effluent from fire extinguishing. Separated from organic solvents, combustible substances and reducing agents. Well closed. Store in an area without drain or sewer access.
8.2 — Exposure controls
- Hand protection
- Handle with gloves.
- Eye protection
- Face shield and safety glasses. Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).
- Skin and body protection
- Wear suitable protective clothing
- Respiratory protection
- Use appropriate respiratory protection if dust is generated.
9.1 — Information on basic physical and chemical properties
- Physical state
- Solid
- Colour
- Bright orange
- Odour
- Odorless
- Odour threshold
- Not applicable
- pH value
- Not applicable
- Relative evaporation rate (butylacetate=1)
- Not applicable
- Melting point
- Decomposes 180 °C
- Freezing point
- Not applicable
- Boiling point
- 100 °C (decomposes)
- Flash point
- Not applicable
- Auto-ignition temperature
- 225 °C
- Decomposition temperature
- Not specified
- Flammability (solid, gas)
- Not flammable
- Vapour pressure
- Not applicable
- Relative vapour density at 20°C
- Not applicable
- Density
- 2.155 g/cu cm at 25 °C
- Solubility
- 35.6 g/100 g water at 20 °C
- Log Pow
- Not applicable
- Viscosity, kinematic
- Not applicable
- Viscosity, dynamic
- Not applicable
- Explosive properties
- Not explosive
- Oxidising properties
- Strong oxidizer
- Explosive limits
- Not applicable
10.1 — Reactivity
- Reactivity
- Reacts violently with reducing agents and organic materials.
10.2 — Chemical stability
- Chemical stability
- Stable under recommended storage conditions.
10.3 — Possibility of hazardous reactions
- Possibility of hazardous reactions
- May explode on heating. The substance is a strong oxidant. It reacts with combustible and reducing materials.
10.4 — Conditions to avoid
- Conditions to avoid
- Avoid contact with incompatible materials and excessive heat.
10.5 — Incompatible materials
- Incompatible materials
- Reducing agents, organic materials, and acids.
10.6 — Hazardous decomposition products
- Hazardous decomposition products
- Not specified
11.1 — Information on toxicological effects
- Acute toxicity
- LD50 rat intravenous 30 mg/kg
- Skin corrosion/irritation
- H314: Causes severe skin burns and eye damage
- Serious eye damage/irritation
- H318: Causes serious eye damage
- Respiratory or skin sensitisation
- H317: May cause an allergic skin reaction; H334: May cause allergy or asthma symptoms or breathing difficulties if inhaled
- Germ cell mutagenicity
- H340: May cause genetic defects
- Carcinogenicity
- H350: May cause cancer
- Specific target organ toxicity (single exposure)
- Not classified (based on available data)
- Specific target organ toxicity (repeated exposure)
- H372: Causes damage to organs through prolonged or repeated exposure
12.1 — Toxicity
- Toxicity information
- Not specified
12.2 — Persistence - degradability
- Persistence - degradability
- Not specified
12.3 — Bioaccumulative potential
- Bioaccumulative potential
- Not specified
12.4 — Mobility in soil
- Mobility in soil
- Not specified
12.6 — Other adverse effects
- Environmental precautions
- Not specified
13.1 — Waste treatment methods
- Additional Info
- Dispose of contents/container in accordance with local, regional, national and international regulations.
14.1 — UN number
- UN-No. (ADR)
- 1439
- UN-No. (IMDG)
- 1439
- UN-No. (IATA)
- 1439
- UN-No. (ADN)
- 1439
- UN-No. (RID)
- 1439
14.2 — UN proper shipping name
- Proper Shipping Name (ADR)
- Ammonium Bichromate
- Proper Shipping Name (IMDG)
- Ammonium Bichromate
- Proper Shipping Name (IATA)
- Ammonium Bichromate
- Proper Shipping Name (ADN)
- Ammonium Bichromate
- Proper Shipping Name (RID)
- Ammonium Bichromate
14.3 — Transport hazard class(es)
- Transport hazard class(es)
- 5.1
14.4 — Packing group
- Packing group (ADR)
- II
- Packing group (IMDG)
- II
- Packing group (IATA)
- II
- Packing group (ADN)
- II
- Packing group (RID)
- II
14.5 — Environmental hazards
- Dangerous for the environment
- Not specified
- Marine pollutant
- Not specified
- Other information
- No supplementary information available
15.1 — Safety, health and environmental regulations/legislation specific for the substance or mixture
- 15.1.1 EU-Regulations
- Not specified
Used as a strong oxidizing agent in chemical demonstrations and as a mordant in historical photographic/printing processes. It is also utilized in the preparation of chromium compounds.
ISO 9001
ISO 14001
GMP
COA with every batch
- Batch Number
- AL-2026-AL00099
- Manufacturing Date
- September-2026
- Expiry Date
- September-2031
- Molecular Weight
- 252.06 g/mol
| Test | Standard | Observed |
|---|---|---|
| Assay | ≥ 99% | 99.5% |
| Moisture Content | ≤ 0.5% | 0.3% |
| Residue on Ignition | ≤ 0.1% | 0.05% |
| Related Substances | None detected | None detected |
| Solubility | Soluble in water | Soluble in water |
The above product is expected to comply with 99% grade specification.
Technical Data Sheet
| Grade | Assay/Purity | Melting/Boiling Point | Moisture/LOD | Residue on Ignition | Related Substances | Solubility |
|---|---|---|---|---|---|---|
| 99% | ≥ 99% | m.p. Decomposes 180 °C | ≤ 0.5% | ≤ 0.1% | None detected | 35.6 g/100 g water at 20 °C |
Related Products
View AllWhy buy from Alpha Chemika
What Our Scientific & Industrial Customers Say
“Speedy delivery, professional staff.”
“One shop stop for all laboratory chemicals requirements.”
“Exactly as advertised.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Completely satisfied with the products and services.”
“Speedy delivery, professional staff.”
“One shop stop for all laboratory chemicals requirements.”
“Exactly as advertised.”
“One shop stop for all laboratory chemicals requirements.”
“Exactly as advertised.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“Exactly as advertised.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Completely satisfied with the products and services.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Completely satisfied with the products and services.”
“Speedy delivery, professional staff.”
“Completely satisfied with the products and services.”
“Speedy delivery, professional staff.”
“One shop stop for all laboratory chemicals requirements.”
Common Questions About Laboratory Chemicals & Solutions
Find answers to common questions about laboratory chemicals, product selection, documentation, ordering, and technical support. Whether you are sourcing chemicals for research, testing, education, manufacturing, or industrial applications, these FAQs can help you make informed purchasing decisions.
Alpha Chemika offers a wide range of laboratory chemicals, reagents, solvents, and specialty products for research, testing, educational, pharmaceutical, and industrial applications.
Product selection depends on factors such as application, required purity, grade, specifications, and intended use. Our team can help you identify suitable products based on your technical requirements.
Yes. Relevant product information and technical documentation can be provided to help you evaluate products for quality, handling, compliance, and application requirements.
Yes. You can share your product list, required quantities, specifications, and delivery requirements with our team for a tailored quotation.
Yes. We support requirements from research laboratories, educational institutions, pharmaceutical companies, manufacturers, distributors, and other scientific and industrial organizations.
Connect with Us for Your Requirements
Have a specific product requirement or need help finding the right chemical for your application? Share your requirements with our team, and we will help you identify suitable products, specifications, quantities, and procurement options.