Cellosolve
- CAS Number
- 110-80-5
- HSN Code
- 29094400
- Molecular Formula
- C4H10O2
- Catalogue Number
- AL1183
- Purity
- 99.5%
- Molecular Weight
- 90.12 g/mol
Complies with : IP | BP | USP | EP | ACS
ISO 9001
ISO 14001
GMP
COA with every batch
Key Properties
2-ethoxyethanol is a hydroxyether that is the ethyl ether derivative of ethylene glycol. It has a role as a protic solvent and a teratogenic agent.
Also known as Ethylene glycol monoethyl ether.
- Catalogue No.
- AL1183
- CAS Number
- 110-80-5
- Molecular Formula
- C4H10O2
- Molecular Weight
- 90.12 g/mol
- HSN Code
- 29094400
- Grade
- AR grade
- Product Form
- Substance
Melting point: -70 °C; Boiling point: 135.7 °C; Flash point: 110 °F (43 °C) (closed cup); Density: 0.9253 g/cu cm at 25 °C; Solubility: Miscible with water.
- Appearance
- Colorless liquid
- Shelf Life
- 2 years
- Packaging
- Available in: 500 ml glass bottle, 2.5 Lt glass bottle
- Storage
- Fireproof. Separated from strong oxidants and food and feedstuffs. Keep in the dark. Cool.
1.1 — Product identifier
- Chemical Name
- Cellosolve
- Catalogue No.
- AL1183
- Product form
- Substance
- CAS Number
- 110-80-5
- EC Number
- 203-804-1
- Grade
- AR grade
- EC Index Number
- 603-140-00-6
- Chemical Formula
- C4H10O2
- HSN Code
- 29094400
- Synonyms
- Ethylene glycol monoethyl ether
1.2 — Relevant identified uses of the substance or mixture and uses advised against
- Use of the substance/mixture
- Solvent in analytical chemistry and precision applications.
- Uses advised against
- Not specified
1.3 — Details of the supplier of the safety data sheet
- Company identification
- Address:- 102, B wing, Savgan Heights, RTO Lane,Andheri (W), Mumbai-400 053Maharashtra, India.
1.4 — Emergency Contact Details
- Phone / e-Mail
- Phone : +91 22 26317055 Mobile : +91 9820385757 e-mail : info@alphachemika.co.in
2.1 — Classification of the substance or mixture
- Classification according to Regulation (EC) No 1272/2008
- Flam. Liq. 3; Acute Tox. 4; Acute Tox. 3; Repr. 1B
- Classification source
- ECHA C&L Inventory via PubChem CID 8076 - hazard classes notified by at least 50% of companies; pictograms and signal word derived from those statements
2.2 — Label elements
- Hazard pictograms
- Flammable, Acute Toxic, Health Hazard
- Signal word
- Danger
- Hazard statements
- H226: Flammable liquid and vapor; H302: Harmful if swallowed; H331: Toxic if inhaled; H360: May damage fertility or the unborn child
2.3 — Other hazards
- Other hazards
- Reproductive toxicity, flammable liquid.
3.1 — Substance
- Name
- Cellosolve
- CAS No.
- 110-80-5
4.1 — Description of first aid measures
- First-aid measures after inhalation
- If this chemical has been inhaled, remove the exposed person to fresh air at once. If breathing has stopped, perform artificial respiration. Keep the person warm and at rest.
- First-aid measures after skin contact
- If this chemical contacts the skin, flush the contaminated skin with water promptly. If this chemical penetrates the clothing, immediately remove the clothing and flush the skin with water promptly. If irritation persists after washing, get medical attention.
- First-aid measures after eye contact
- If this chemical contacts the eyes, immediately wash (irrigate) the eyes with large amounts of water, occasionally lifting the lower and upper lids. Get medical attention immediately.
- First-aid measures after ingestion
- If this chemical has been swallowed, get medical attention immediately.
4.2 — Most important symptoms and effects, both acute and delayed
- Symptoms relating to use
- Headache, dizziness, nausea, irritation of eyes and skin.
4.3 — Indication of any immediate medical attention and special treatment needed
- General information
- Treat symptomatically. Show this safety data sheet to the treating physician.
5.1 — Extinguishing media
- Suitable extinguishing media
- Water spray, carbon dioxide, dry chemical powder, foam.
- Unsuitable extinguishing media
- Not specified
5.2 — Special hazards arising from the substance or mixture
- Special procedures
- Flammable liquid; may produce toxic fumes in a fire.
5.3 — Advice for firefighters
- Protection during firefighting
- Do not enter fire area without proper protective equipment, including respiratory protection.
6.1.1 — For non-emergency personnel
- Emergency procedures
- Evacuate area and ventilate. Contain spill and absorb with inert material.
6.3 — Methods and material for containment and cleaning up
- Methods for cleaning up
- Remove all ignition sources. Personal protection: protective clothing, protective gloves and filter respirator for organic gases and vapours adapted to the airborne concentration of the substance. Ventilation. Collect leaking liquid in sealable containers.
6.4 — Reference to other sections
- Reference
- Not specified
7.1 — Precautions for safe handling
- Precautions for safe handling
- Use in a fume hood. Wear appropriate personal protective equipment (PPE).
- Hygiene measures
- Wash hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work.
7.2 — Conditions for safe storage, including any incompatibilities
- Storage conditions
- Fireproof. Separated from strong oxidants and food and feedstuffs. Keep in the dark. Cool.
8.2 — Exposure controls
- Hand protection
- Protective gloves (e.g. nitrile rubber)
- Eye protection
- Chemical safety goggles or safety glasses
- Skin and body protection
- Wear suitable protective clothing
- Respiratory protection
- Use appropriate respiratory protection if ventilation is inadequate.
9.1 — Information on basic physical and chemical properties
- Physical state
- Liquid
- Colour
- Colorless
- Odour
- Sweet, pleasant, ether-like odor
- Odour threshold
- Not determined
- pH value
- Not applicable
- Relative evaporation rate (butylacetate=1)
- 0.5
- Melting point
- -70 °C
- Freezing point
- Not applicable
- Boiling point
- 135.7 °C
- Flash point
- 110 °F (43 °C) (closed cup)
- Auto-ignition temperature
- 455 °F (235 °C)
- Decomposition temperature
- Not determined
- Flammability (solid, gas)
- Not applicable
- Vapour pressure
- 5.31 mm Hg at 25 °C
- Relative vapour density at 20°C
- Relative vapor density (air = 1): 3.1
- Density
- 0.9253 g/cu cm at 25 °C
- Solubility
- Miscible with water
- Log Pow
- -0.32
- Viscosity, kinematic
- Not determined
- Viscosity, dynamic
- Not determined
- Explosive properties
- Not explosive
- Oxidising properties
- Not oxidizing
- Explosive limits
- 1.2 - 11.5% (v/v) in air
10.1 — Reactivity
- Reactivity
- Stable under normal conditions. Avoid strong oxidizing agents.
10.2 — Chemical stability
- Chemical stability
- Stable under recommended storage conditions.
10.3 — Possibility of hazardous reactions
- Possibility of hazardous reactions
- The substance can form explosive peroxides. Reacts with strong oxidants. This generates fire and explosion hazard.
10.4 — Conditions to avoid
- Conditions to avoid
- Avoid contact with incompatible materials and excessive heat.
10.5 — Incompatible materials
- Incompatible materials
- Strong oxidizers, strong acids, and bases.
10.6 — Hazardous decomposition products
- Hazardous decomposition products
- Hazardous decomposition products formed under fire conditions. - Carbon oxides.
11.1 — Information on toxicological effects
- Acute toxicity
- LD50 Mouse ip 1700 mg/kg bw; LD50 Rat ip 2000 mg/kg bw; LD50 Rat dermal 3900 mg/kg
- Skin corrosion/irritation
- Not classified (based on available data)
- Serious eye damage/irritation
- Not classified (based on available data)
- Respiratory or skin sensitisation
- Not classified (based on available data)
- Germ cell mutagenicity
- Not classified (based on available data)
- Carcinogenicity
- Not classified (based on available data)
- Specific target organ toxicity (single exposure)
- Not classified (based on available data)
- Specific target organ toxicity (repeated exposure)
- Not classified (based on available data)
12.1 — Toxicity
- Toxicity information
- Not specified
12.2 — Persistence - degradability
- Persistence - degradability
- Not specified
12.3 — Bioaccumulative potential
- Bioaccumulative potential
- Not specified
12.4 — Mobility in soil
- Mobility in soil
- Not specified
12.6 — Other adverse effects
- Environmental precautions
- Not specified
13.1 — Waste treatment methods
- Additional Info
- Dispose of contents/container in accordance with local, regional, national and international regulations.
14.1 — UN number
- UN-No. (ADR)
- 1171
- UN-No. (IMDG)
- 1171
- UN-No. (IATA)
- 1171
- UN-No. (ADN)
- 1171
- UN-No. (RID)
- 1171
14.2 — UN proper shipping name
- Proper Shipping Name (ADR)
- Ethylene glycol monoethyl ether
- Proper Shipping Name (IMDG)
- Ethylene glycol monoethyl ether
- Proper Shipping Name (IATA)
- Ethylene glycol monoethyl ether
- Proper Shipping Name (ADN)
- Ethylene glycol monoethyl ether
- Proper Shipping Name (RID)
- Ethylene glycol monoethyl ether
14.3 — Transport hazard class(es)
- Transport hazard class(es)
- 3
14.4 — Packing group
- Packing group (ADR)
- III
- Packing group (IMDG)
- III
- Packing group (IATA)
- III
- Packing group (ADN)
- III
- Packing group (RID)
- III
14.5 — Environmental hazards
- Dangerous for the environment
- Not specified
- Marine pollutant
- Not specified
- Other information
- No supplementary information available
15.1 — Safety, health and environmental regulations/legislation specific for the substance or mixture
- 15.1.1 EU-Regulations
- Not specified
Used in analytical and precision applications requiring purer cellosolve solvent.
ISO 9001
ISO 14001
GMP
COA with every batch
- Batch Number
- AL-2026-AL0423A
- Manufacturing Date
- September-2026
- Expiry Date
- September-2031
- Molecular Weight
- 90.12 g/mol
| Test | Standard | Observed |
|---|---|---|
| Purity | 99.5% min | 99.7% |
| Density | 0.93 g/mL | 0.93 g/mL |
| Boiling Point | 134 °C | 134.5 °C |
| Moisture Content | <0.5% | 0.3% |
| Residue on Ignition | <0.01% | 0.005% |
| Related Substances | None detected | None detected |
The above product is expected to comply with AR grade grade specification.
Technical Data Sheet
| Grade | Assay/Purity | Melting/Boiling Point | Moisture/LOD | Residue on Ignition | Related Substances | Solubility |
|---|---|---|---|---|---|---|
| AR grade | 99.5% | m.p. -70 °C; b.p. 135.7 °C | <0.5% | <0.01% | None detected | Miscible with water |
Related Products
View AllWhy buy from Alpha Chemika
What Our Scientific & Industrial Customers Say
“Speedy delivery, professional staff.”
“One shop stop for all laboratory chemicals requirements.”
“Exactly as advertised.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Completely satisfied with the products and services.”
“Speedy delivery, professional staff.”
“One shop stop for all laboratory chemicals requirements.”
“Exactly as advertised.”
“One shop stop for all laboratory chemicals requirements.”
“Exactly as advertised.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“Exactly as advertised.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Alpha Chemika products are of excellent quality. Highly satisfied.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Completely satisfied with the products and services.”
“From ordering to shipping, every course of action was smooth. Timely delivery.”
“Completely satisfied with the products and services.”
“Speedy delivery, professional staff.”
“Completely satisfied with the products and services.”
“Speedy delivery, professional staff.”
“One shop stop for all laboratory chemicals requirements.”
Common Questions About Laboratory Chemicals & Solutions
Find answers to common questions about laboratory chemicals, product selection, documentation, ordering, and technical support. Whether you are sourcing chemicals for research, testing, education, manufacturing, or industrial applications, these FAQs can help you make informed purchasing decisions.
Alpha Chemika offers a wide range of laboratory chemicals, reagents, solvents, and specialty products for research, testing, educational, pharmaceutical, and industrial applications.
Product selection depends on factors such as application, required purity, grade, specifications, and intended use. Our team can help you identify suitable products based on your technical requirements.
Yes. Relevant product information and technical documentation can be provided to help you evaluate products for quality, handling, compliance, and application requirements.
Yes. You can share your product list, required quantities, specifications, and delivery requirements with our team for a tailored quotation.
Yes. We support requirements from research laboratories, educational institutions, pharmaceutical companies, manufacturers, distributors, and other scientific and industrial organizations.
Connect with Us for Your Requirements
Have a specific product requirement or need help finding the right chemical for your application? Share your requirements with our team, and we will help you identify suitable products, specifications, quantities, and procurement options.